Borri UPSaver

Borri UPSaver

The Borri UPSaver and UPSaver 3vo UPS (uninterruptible power supply) is a very high efficiency, multi function and fully adaptable three phase modular UPS system supplying online double conversion power. The power modules provide flexibility of the system and can be configured as either a standalone unit or in a modular framework.

Overview

The Borri UPSaver is available from 400kVA and can be scaled up to 12.8MW and the UPSaver 3vo is available from 670kVA and is scalable up to 21MW. Both modular UPS systems achieve a maximum efficiency of 99.5%

UPSaver technical specification

WARRANTY

1 Year Parts (upgradable to 5 Years)

RATING KVA

400 - 1600

N NOMINAL POWER

400kW - 1600kW

N+1 NOMINAL POWER

200kW - 1400kW

DIMENSIONS (WxDxH)

2350x 970x 2100 (400kVA) 2950x 970x 2100 (600kVA) 3900x 970x 2100 (800kVA) 4500x 970x 2100 (1000kVA) 5100x 970x 2100 (1200 kVA) 6800x 970x 2100 (1400kVA) 7400x 970x 2100 (1600kVA)

WEIGHT

1660KG (400kVA) 2260KG (600kVA) 2920KG (800kVA) 3590KG (1000kVA) 4190KG  (1200 kVA) 4960KG (1400kVA)5560KG (1600kVA)

INPUT PHASE

Three Phase

INPUT VOLTAGE TOLERANCE RANGE

'-20%, +15% (rectifier); ±10% (bypass)

INPUT FREQUENCY

50/60 Hz, 45 to 65 Hz

OUTPUT PHASE

Three Phase

OUTPUT POWER FACTOR

Any power factor (leading or lagging) up to 1, without power derating

OUTPUT WAVEFORM

Sinusoidal

OUTPUT VOLTAGE

380/400/415 Vac 3-phase with neutral

OUTPUT FREQUENCY

50/60 Hz

OUTPUT EFFICIENCY

Up to 99.5%

BATTERY CONFIGURATION

External 360 to 372 cells, VRLA (other options)

OPERATING TEMPERATURE TOLERANCE

0 - 40°C

RELATIVE HUMIDITY

<95% (non-condensing)

COMMUNICATION

Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter

OPTIONAL COMMS

extended VFC

PARALLEL

Up to 8 UPS, for a total of 12.8 MW

FUNCTIONS

Optional: Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (2 UPS systems); other options on request

Resources

Borri UPSaver 3vo Leaflet

Borri UPSaver Leaflet

Related products

Huawei UPS5000-E

25kVA - 800kVA

Modular

A hotswap modular UPS scalable up to multi-megawatt solution for medium to large data centres

Ideal for medium to large sized data centres, the UPS5000-E is a modular hot-swappable design expandable from 30kVA to 800kVA .The modular architecture simplifies operations and maintenance (O&M) and greatly improves system availability.

Huawei UPS5000-H Series

400kVA - 1600kVA

Modular

A hotswap modular UPS scalable up to multi megawatt solution for medium to large data centres

The hot swappable modules make maintaining and expanding the UPS solution quick and easy which increases the availability of the data centre. The control module and power module uses a redundant design which ensures high system reliability. Also featuring a Super ECO (S-ECO) mode that boosts system efficiency to a remarkable 99%, the UPS5000-H is one of the most efficient UPS systems available on the market.

Legrand Keor HPE

400kVA - 1600kVA

Modular

Optimised three phase modularity consisting of hot swap single phase modules

The Legrand Keor HPE UPS (uninterruptible power supply) is a very high efficiency, online double conversion three phase modular UPS system with 3-level IGBT technology. Each system is equipped with either a 7 inch or 10 inch smart, interactive, LCD screen to control the operating parameters of the UPS.

Additional Features

  • 4 level modularity
  • Hot swappable batteries and modules for easy maintenance
  • High efficiency even at low loads
  • 4 operation modes - double conversion (VFI), active filtering (VI), ECO mode (VFD) and ultra high efficiency mode (VFD)
  • Detection of circuitry and input disconnection for maximum operator safety
  • Unity input power factor

UPSaver 3vo technical specification

WARRANTY

1 Year Parts (upgradable to 5 Years)

RATING KVA

670 - 2670

N NOMINAL POWER

670kW - 2670kW

NO OF MODULES

2-8

DIMENSIONS (WxDxH)

2450x 970x 2100 (670kVA) 3050x 970x 2100 (1000kVA) 4100x 970x 2100 (1340kVA)4700x 970x 2100 (1670 kVA) 5700x 970x 2100 (2000 kVA) 

WEIGHT

1800KG (670kVA) 2540KG (1000kVA) 3170KG (1340kVA) 3900KG (1670kVA) 4700KG  (2000kVA) 

BATTERY CONFIGURATION

External 360 to 372 cells, VRLA (other options)

INPUT PHASE

Three Phase

INPUT VOLTAGE TOLERANCE RANGE

'-20%, +15% (rectifier); ±10% (bypass)

INPUT FREQUENCY

50/60 Hz, 45 to 65 Hz

PARALLEL

Up to 8 UPS, for a total of 12.8 MW

OUTPUT PHASE

Three Phase

OUTPUT POWER FACTOR

Any power factor (leading or lagging) up to 1, without power derating

OUTPUT WAVEFORM

Sinusoidal

OUTPUT VOLTAGE

380/400/415 Vac 3-phase with neutral

OUTPUT FREQUENCY

50/60 Hz

OUTPUT EFFICIENCY

Up to 99.5%

OPERATING TEMPERATURE TOLERANCE

0 - 40°C

RELATIVE HUMIDITY

<95% (non-condensing)

COMMUNICATION

Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter

OPTIONAL COMMS

extended VFC

FUNCTIONS

Optional: Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (2 UPS systems); other options on request